Iraq Ug Cable 3X150mm2 18/30kv XLPE/PVC with Armour

Model NO.: UG cable 3x150mm2
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE, SABS
Model: YJV
Brand: Jiapu
Standards: ASTM, IEC, DIN, CSA, BS...
Exported Country: Kenya, South Africa, Iraq, Pakistan, etc.
Trademark: JP
Transport Package: Wooden Drums or Wooden-Steel Drums
Specification: 12/20 (24) kV 3x150
Origin: China
HS Code: 8544601200
Model NO.: UG cable 3x150mm2
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE, SABS
Model: YJV
Brand: Jiapu
Standards: ASTM, IEC, DIN, CSA, BS...
Exported Country: Kenya, South Africa, Iraq, Pakistan, etc.
Trademark: JP
Transport Package: Wooden Drums or Wooden-Steel Drums
Specification: 12/20 (24) kV 3x150
Origin: China
HS Code: 8544601200
UG cable 3x150mm2 copper 18/30 (36) kV XLPE insualted/ PVC sheath with armour to Iraq

Product Description

Standards of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
The cable is manufactured according to IEC 60502.2, IEC 60502.1, AS/NZS 1429.1, AS/NZS 5000.1, BS 6622/7835, BS 5467, BS 6746, BS 6346, VDE 0276, ASTM, ABNT etc. It is suitable to be installed in the power line with rated voltage from (U0/U)0.6/1kV to 19/33kV for power transmission.
 
Application of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
The electric cable is applied to transmit and distribute power in power transmission and distribution system of 1kV~35kV or lower. It is widely adopted in the fields including power, construction, industry, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power  cable and in partial re-place of PVC insulation or XLPE power cable.

Type & Designation of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
Type Description Applications
N2XY/N2XSEY
NA2XY/NA2XSEY
Cu or AL conductor XLPE insulated PVC sheathed power cables. For laying indoors, in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts.
N2X2Y/N2XSE2Y
NA2X2Y/NA2XSE2Y
Cu or AL conductor XLPE insulated PE sheathed power cables.
N2XBY/N2XSEBY
NA2XBY/NA2XSEBY
Cu or AL conductor XLPE insulated PVC sheathed internal steel tape armoured power cables. For laying indoors, in tunnels, in ducts and underground. Able to bear extermal mechanical force but not large pulling forces, Impermissible to use single core cable in A.C circuit.
N2XB2Y/N2XSEB2Y
NA2XB2Y/NA2XSEB2Y
Cu or AL conductor XLPE insulated PE sheathed internal steel tape armoured power cables.
N2XRY/N2XSERY
NA2XRY/NA2XSERY
Cu or AL conductor XLPE insulated PVC sheathed internal steel wire armoured power cables. For laying in underground areas along route with large difference of elevation, in shafts and in water, able to bear a corresponding pulling forces and external mechanical forces.
N2XR2Y/N2XSER2Y
NA2XR2Y/NA2XSER2Y
Cu or AL conductor XLPE insulated PE sheathed internal steel wire armoured power cables.
 
Cable Properties of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
Special features which we can offer for LV and MV cables:
* Watertight construction (both radial and longitudinal).
* Resistant to heavy vibration.
* Available in long delivery lengths to reduce number of joints.
* Corrosion-free screen area.
* Copper or aluminum conductor up to 2500mm².
* Different options for outer PE jackets (LDPE, MDPE & HDPE).
* Different options for PVC, LSF, LSZH & FRPVC, being anti-termite or UV resistant as per 
   BS 7835, IEC 60332 etc.
* Strippable insulation screen.
* Increased armour conductivity by insertion of hard drawn copper wires in armour.
 
The maximum rated temperature of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
XLPE insulated,the maximum operating temperature of conductor shall exceed 90ºCwhen the cable is used for long not period. The temperature of conductor shall not exceed 250ºC at short circuit for 5 seconds.
PVC insulated,the maximum operating temperature of conductor shall exceed 90ºC or 70 ºC  when the cable is used for long not period. PVC insulated the temperature of conductor shall not exceed 160ºC at short circuit for 5 seconds.
 
Installation requirement of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
The installation of cable is not limited by the difference of elevation along the route. The ambient temperature should not be below 0ºC during installation. The permissible bending radius for cable shall be complied with the following regulations:
For single-core: R>20(D+d) +/-5%
For multi-core: R>15(D+d) +/-5%
Where:R-bending radius (mm) , D-overall diameter of the cable (mm) , d-diameter of conductor (mm).
Single core cable of using in AC circuit shall be without armour or with steel wire armour and shall not be laid in magnetic ducs.
 
Rated voltage, No. of core and range of sectional area
 
Rate Voltage(kv): 0.6/1kV  1.8/3kV    3.6/6kV    6/10kV      8.7/15kV   12/20kV  
                         18/30kV  21/35kV  
    Equivalent to : 0.6/1kV  1.9/3.3kV  3.8/6.6kV  6.35/11kV  8.7/15kV   12.7/22kV 
                         19/33kV   21/35kV
 
No. of core and sectional area(mm2):
 
1 Core 1.5-800    25-800    25-1200    25-1200    35-1200    50-1200    50-1200 
          50-1200 
2 Core 1.5-185     25-185 
3 Core 1.5-400     25-400     25-400     25-400     35-400     50-400     50-400  
          50-400 
4 Core 2.5-400     25-400 
5 Core 2.5-400     25-400

 
Contact: Daiana
Marketing Manager
Henan Jiapu Cable Co., Ltd
Direct Tel: +86-371-6866 5329 Ext.611
Direct Fax: +86-371-6938 6788
Mobile No.: +86-135 9881 0343
 
website: www.jiapucable.com UG cable 3x150mm2 copper 18/30 (36) kV XLPE insualted/ PVC sheath with armour to Iraq

Product Description

Standards of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
The cable is manufactured according to IEC 60502.2, IEC 60502.1, AS/NZS 1429.1, AS/NZS 5000.1, BS 6622/7835, BS 5467, BS 6746, BS 6346, VDE 0276, ASTM, ABNT etc. It is suitable to be installed in the power line with rated voltage from (U0/U)0.6/1kV to 19/33kV for power transmission.
 
Application of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
The electric cable is applied to transmit and distribute power in power transmission and distribution system of 1kV~35kV or lower. It is widely adopted in the fields including power, construction, industry, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power  cable and in partial re-place of PVC insulation or XLPE power cable.

Type & Designation of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
Type Description Applications
N2XY/N2XSEY
NA2XY/NA2XSEY
Cu or AL conductor XLPE insulated PVC sheathed power cables. For laying indoors, in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts.
N2X2Y/N2XSE2Y
NA2X2Y/NA2XSE2Y
Cu or AL conductor XLPE insulated PE sheathed power cables.
N2XBY/N2XSEBY
NA2XBY/NA2XSEBY
Cu or AL conductor XLPE insulated PVC sheathed internal steel tape armoured power cables. For laying indoors, in tunnels, in ducts and underground. Able to bear extermal mechanical force but not large pulling forces, Impermissible to use single core cable in A.C circuit.
N2XB2Y/N2XSEB2Y
NA2XB2Y/NA2XSEB2Y
Cu or AL conductor XLPE insulated PE sheathed internal steel tape armoured power cables.
N2XRY/N2XSERY
NA2XRY/NA2XSERY
Cu or AL conductor XLPE insulated PVC sheathed internal steel wire armoured power cables. For laying in underground areas along route with large difference of elevation, in shafts and in water, able to bear a corresponding pulling forces and external mechanical forces.
N2XR2Y/N2XSER2Y
NA2XR2Y/NA2XSER2Y
Cu or AL conductor XLPE insulated PE sheathed internal steel wire armoured power cables.
 
Cable Properties of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
Special features which we can offer for LV and MV cables:
* Watertight construction (both radial and longitudinal).
* Resistant to heavy vibration.
* Available in long delivery lengths to reduce number of joints.
* Corrosion-free screen area.
* Copper or aluminum conductor up to 2500mm².
* Different options for outer PE jackets (LDPE, MDPE & HDPE).
* Different options for PVC, LSF, LSZH & FRPVC, being anti-termite or UV resistant as per 
   BS 7835, IEC 60332 etc.
* Strippable insulation screen.
* Increased armour conductivity by insertion of hard drawn copper wires in armour.
 
The maximum rated temperature of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
XLPE insulated,the maximum operating temperature of conductor shall exceed 90ºCwhen the cable is used for long not period. The temperature of conductor shall not exceed 250ºC at short circuit for 5 seconds.
PVC insulated,the maximum operating temperature of conductor shall exceed 90ºC or 70 ºC  when the cable is used for long not period. PVC insulated the temperature of conductor shall not exceed 160ºC at short circuit for 5 seconds.
 
Installation requirement of 18/30 (36) KV XLPE Insulated Steel Wire Armoured Electrical Power Cable
 
The installation of cable is not limited by the difference of elevation along the route. The ambient temperature should not be below 0ºC during installation. The permissible bending radius for cable shall be complied with the following regulations:
For single-core: R>20(D+d) +/-5%
For multi-core: R>15(D+d) +/-5%
Where:R-bending radius (mm) , D-overall diameter of the cable (mm) , d-diameter of conductor (mm).
Single core cable of using in AC circuit shall be without armour or with steel wire armour and shall not be laid in magnetic ducs.
 
Rated voltage, No. of core and range of sectional area
 
Rate Voltage(kv): 0.6/1kV  1.8/3kV    3.6/6kV    6/10kV      8.7/15kV   12/20kV  
                         18/30kV  21/35kV  
    Equivalent to : 0.6/1kV  1.9/3.3kV  3.8/6.6kV  6.35/11kV  8.7/15kV   12.7/22kV 
                         19/33kV   21/35kV
 
No. of core and sectional area(mm2):
 
1 Core 1.5-800    25-800    25-1200    25-1200    35-1200    50-1200    50-1200 
          50-1200 
2 Core 1.5-185     25-185 
3 Core 1.5-400     25-400     25-400     25-400     35-400     50-400     50-400  
          50-400 
4 Core 2.5-400     25-400 
5 Core 2.5-400     25-400

 
Contact: Daiana
Marketing Manager
Henan Jiapu Cable Co., Ltd
Direct Tel: +86-371-6866 5329 Ext.611
Direct Fax: +86-371-6938 6788
Mobile No.: +86-135 9881 0343
 
website: www.jiapucable.com